PART No. | TYPE No. | Description |
---|---|---|
3111401 3111402 |
RF 50 78L RF 50 78L Z |
Standard cable Fire retardant cable |
Construction | ||
Copper tube 9.40±0.10 |
Material Diameter, mm |
Inner Conductor |
Physically foamed PE 22.40±0.40 |
Material Diameter, mm |
Insulation |
Ring corrugated copper 25.60±0.30 |
Material Diameter, mm |
Outer Conductor |
PE or fire retardant PE 27.90±0.30 |
Material Diameter, mm |
Jacket |
Mechanical properties | ||
127 254 500 |
Single Repeated Moving |
Bending radius , mm |
1590 | Pulling strength, N | |
1.35 | Crush resistance, kg/mm | |
Store -70~+85 Installation -40~+60 Operation -55~+85 Store -30~+80 Installation -25~+60 Operation -30~+80 |
PE jacket
Fire retardant |
Recommend temperature , ℃ |
Electrical properties | ||
50±2 | Impedance,Ω | |
75 | Capacitance, PF/m | |
0.19 | Inductance,μH/m | |
89 | Propagation velocity, % | |
6.0 | DC breakdown voltage, kV | |
>5×102 | Insulation resistance, MΩ•km | |
91 | Peak power, kW | |
>>120 | Screening attenuation, dB | |
5.0 | Cut-off frequency, GHz |
Attenuation and average power | ||
---|---|---|
Power rate @40℃,kW |
Nom. attenuation @20℃,dB/100m |
Frequency MHz |
23.37 | 0.36 | 10 |
5.05 | 1.67 | 200 |
3.29 | 2.55 | 450 |
2.42 | 3.48 | 800 |
2.26 | 3.70 | 900 |
2.19 | 3.84 | 960 |
2.14 | 3.93 | 1000 |
1.71 | 4.91 | 1500 |
1.54 | 5.44 | 1800 |
1.46 | 5.77 | 2000 |
1.38 | 6.09 | 2200 |
1.28 | 6.55 | 2500 |
1.15 | 7.27 | 3000 |
• Maximum attenuation value shall be 105% of the nominal attenuation value |
||
VSWR | ||
≤1.15 | 820~960 MHz | |
≤1.15 | 1700~2200 MHz | |
≤1.15 | 2300~2400 MHz | |
Standards | ||
Compliant | 2011/65/EU |